Julat & aplikasi kuasa yang disyorkan
|
Julat kuasa |
Aplikasi biasa |
|
7-50kva |
Rumah, pejabat kecil, sandaran telekomunikasi |
|
60-200kva |
Kedai, klinik, kilang kecil |
|
250-800kva |
Hotel, hospital, pusat data |
|
1000-2500kva |
Loji perindustrian yang besar, utiliti, perlombongan |
Spesifikasi Teknikal (Model Contoh)
|
Model No. |
Kuasa siap sedia |
Kuasa Perdana |
Model enjin |
Voltan |
Kekerapan |
Konfigurasi |
|
P30 |
30kva |
27kva |
1103A-33G |
230/400V |
50Hz |
Senyap / terbuka |
|
P150 |
150kva |
135kva |
1106A-70TAG2 |
230/400V |
50Hz |
Senyap / treler |
|
P500 |
500kva |
450kva |
2506a - e15tag2 |
400/690V |
50Hz |
Kontena |
|
P2000 |
2000kva |
1800kva |
4016-61trg3 |
400/690V |
50Hz |
Kontena |
Perkins Generator menetapkan parameter utama
|
0Hz, COSф =0.8, 400/230V 3p 4W |
Enjin diesel |
alternator |
Dimensi luaran (mm) |
berat kasar (kg) |
||||
|
Model |
kuasa dinilai (kW/kva) |
Kuasa siap sedia (kW/kva) |
Model |
kuasa (kw) |
Model |
kuasa dinilai (kW/kva) |
||
|
8gf |
8/10 |
8.8/11 |
403A-11G1 |
8 |
PI044E |
8/10 |
1580x810x930 |
380 |
|
10gf |
10/12.5 |
11/13.8 |
403A-15G1 |
12 |
PI044F |
10/12.5 |
1580x810x930 |
500 |
|
16gf |
16/20 |
18/22.5 |
404A-22G1 |
18 |
PI144D |
16/20 |
1580x810x990 |
540 |
|
24gf |
24/30 |
26/32.5 |
1103A-33G |
28 |
PI144G |
24/30 |
1580x810x1165 |
660 |
|
28gf |
28/35 |
30.8/38.5 |
1103A-33G |
28 |
PI144H |
28/35 |
1595x810x1150 |
660 |
|
32gf |
32/40 |
35.2/44 |
1103A-33TG1 |
41 |
PI144J |
32/40 |
1595x810x1150 |
730 |
|
40gf |
40/50 |
44/55 |
1103A-33TG1 |
41 |
UCI224D |
40/50 |
1580x810x1165 |
730 |
|
58gf |
58/72.5 |
63.8/80 |
1104A-44TG1 |
58 |
UCI224F |
58/72.5 |
1760x810x1165 |
780 |
|
96GF |
96/120 |
105.6/132 |
1106A-70TG1 |
119 |
UCI274E |
96/120 |
2240x960x1315 |
1030 |
|
112gf |
112/140 |
123.2/154 |
1106A-70TG1 |
119 |
UCI274E |
112/140 |
2190x810x1365 |
1250 |
|
128gf |
128/160 |
140/176 |
1106A-70TAG2 |
130 |
UCI274F |
128/160 |
2240x960x1315 |
1300 |
|
144gf |
144/180 |
158/198 |
1106A-70TAG3 |
157 |
UCI274G |
144/180 |
2345x810x1365 |
1300 |
|
160gf |
160/200 |
176/220 |
1106A-70TAG4 |
174 |
UCI274H |
160/200 |
2240x960x1590 |
1300 |
|
200gf |
200/250 |
220/275 |
1506a - e88tag3 |
228 |
UCD274K |
200/250 |
2430x960x1590 |
2170 |
|
240gf |
240/300 |
264/330 |
1506a - e88tag5 |
273 |
HCI44D |
240/300 |
3030x1120x1800 |
2500 |
|
300gf |
300/375 |
330/412.5 |
2206c - e13tag3 |
349 |
HCI444F |
300/375 |
3280x1130x1950 |
3300 |
|
360gf |
360/450 |
400/500 |
2506c - e15tag1 |
396 |
HCI544C |
360/450 |
3280x1130x1950 |
3800 |
|
400gf |
400/500 |
440/550 |
2506c - e15Tag2 |
435 |
HCI544C |
400/500 |
3310x1180x1950 |
3940 |
|
500gf |
500/625 |
550/690 |
2806a - e18tag1a |
555 |
HCI544FS |
500/625 |
3380x1500x2100 |
4706 |
|
640gf |
640/800 |
720/900 |
4006-23tag3a |
705 |
HCI634G |
640/800 |
4450x1750x2350 |
4706 |
|
720gf |
720/900 |
792/990 |
4008tag1a |
767 |
LVI1634D |
720/900 |
4850x1870x2350 |
7611 |
|
800gf |
800/1000 |
880/1100 |
4008tag2a |
899 |
HCI634J |
800/1000 |
4760x1995x2330 |
7611 |
|
1000gf |
1000/1250 |
1100/1375 |
4012-46TWG2A |
1055 |
PI734A |
1000/1250 |
4900x1860x2350 |
9154 |
|
1200gf |
1200/1500 |
1320/1650 |
4012-46tag2a |
1267 |
P1734C |
1200/1500 |
4900x1860x2350 |
11580 |
|
1320gf |
1320/1650 |
1452/1815 |
4012-46tag3a |
1440 |
P1734D |
1320/1650 |
4900x1860x2350 |
11580 |
|
1500gf |
1500/1875 |
1650/2062 |
4016tag1a |
1537 |
PI734E |
1500/1875 |
6800x2780x3500 |
12000 |
|
1600gf |
1600/2000 |
1760/2200 |
4016tag2a |
1766 |
PI734F |
1600/2000 |
6800x2780x3500 |
12000 |
|
1800gf |
1800/2250 |
1980/2475 |
4016-61trg3 |
1975 |
PI734G |
1800/2250 |
8000x3120x4400 |
13400 |
Ciri -ciri utama
- Dikuasakan oleh enjin Perkins yang tulen
- Julat kuasa lebar dari 7kva -2500kva
- FUEL - Cekap, rendah - Reka bentuk pelepasan
- Konfigurasi Pelbagai: Buka, Senyap, Treler, Kontena
- CE/ISO yang diperakui untuk pasaran global



Cool tags: Set Generator Perkins, Pembekal Set Generator China Perkins, Kilang